Moisture Detection & Monitoring Applications

We work directly with Architects, Engineers and Consultants from the design stage to ensure optimal building envelope performance.

ROOF AREAS

Bitumen Roof MembraneBecause every roof membrane is unique, Detec Systems can be deployed on low-slope roofs in several ways. Whether your roof is Exposed/Conventional, Protected/Inverted, or Green, we work with you to design a system that fits your unique application.

For automated, permanent monitoring in new construction or re-roof projects:

• A custom grid of Detec’s proprietary Moisture Detection Tape (MDT) is installed under the entire roof membrane

• Penetrations are monitored from below the roof deck

• The grid locates defects so that your maintenance staff can quickly repair the membrane failure

• The system continuously monitors the roof membrane for signs of moisture intrusion

• Local weather data is also used in our analysis. Reports are displayed in graph or site plan format so that accurate trending information is made available to the appropriate parties

 

For manual forensic scanning of existing roofs and quality assurance on new roofs:

• Our IntegriScan™ technology uses electrical conductance testing to pinpoint a membrane breach

• Yearly scanning using IntegriScan is recommended when a permanent system is not in place

WALLS, WINDOWS & DOORWAYS

perimeter moisture monitoringAll buildings leak. There's no way to avoid it. Detec offers peace of mind. If excessive unseen moisture accumulates within your building envelope, the system will detect, analyze and report the intrusion so that appropriate action can be taken to correct the problem before it becomes a costly repair.

Detec's Moisture Detection Tape (MDT) is applied to the the entire perimeter of the building at the base of the exterior wall cavity and under all windows, door sills, spacer joints, and wall penetrations where water could find its way in. As well, small probes are inserted at regular intervals into the wall sheathing to monitor for water absorption. When water comes in contact with our MDT or probes, the resistance of the low-voltage current is altered, informing us of a moisture event.

 

 

 

 

 

 

 

 

 

 

INTERSTITIAL SPACES

Interstitial SpacesMost interstitial spaces are only seen infrequently by maintenance crews, and are extremely vulnerable to damage from unseen moisture intrusion. Installing a Detec System can greatly reduce the risk of water damage in these sensitive areas.

Proactively Monitor Your Access Floors and High Risk Floors for Flooding
From hospitals with entire interstitial floors to data centers with raised access floors, the Detec Moisture Detection & Monitoring System (MDMS) helps solve the problems related to unseen flooding anywhere sensitive equipment or merchandise is located. Early detection, pinpoint location and immediate action are the solution. Detec Systems keeps constant watch so facilities managers are prepared to respond quickly and can minimize unexpected flood damage.  

SPECIALTY CASES

Monitor for moisture  anywhereFrom institutional kitchens to parking garages to a 200 year-old library, Detec has proven to be successful at solving unique moisture intrusion problems. Call us today to see how we can help you with your project.

 

 

 

 

 

ENCLOSURE PERFORMANCE

Online moisture reportingThe true value of Detec is realized in measuring the envelope performance of your building. Most building enclosures are designed to handle a small amount of moisture without being overwhelmed. When their natural ability to allow moisture to escape has been compromised, the damaging effects of the hidden moisture can go unchecked, resulting in unexpected repair costs, excessive construction waste and possibly expensive litigation.

Detec Improves Enclosure Performance by:

• Ensuring buildings are constructed more efficiently through early identification of moisture intrusion events

• Ensuring moisture intrusion events are reported and analyzed throughout the service life of the building

• Directing your maintenance dollars to where they are needed most by minimizing costly repairs and construction waste

• Providing invaluable wetting and drying trend data that correlates directly with weather service data

RESERVOIRS

Detec is perfect for ReservoirsDetec has become an important component in the construction of municipal reservoirs. More specifically, a critical component in the installation and maintenance of the waterproof membranes on the reservoir lids. The Seattle Public Utility researched and chose Detec to implement its unique three step program for a higher standard-of-care for membranes.

Step one involved the IntegriScan quality control to verify that the membrane was watertight as it was being installed. Breaches in the membrane were located and quickly repaired by the contractor thereby negating the need for a cumbersome and ineffective flood test.

Step two was the installation of the LeakLocator System directly on top of the membrane and under the overburden. The grid array leak detection sensors are terminated on test fixtures in a weather tight enclosure. This provides quick access and rapid testing for any membrane damage.

Step three will be scheduled monitoring of the membrane for years to come, ensuring that hidden leaks won’t compromise the population’s water supply. If leaks do occur as a result of a seismic or other event, the LeakLocator System will facilitate quick detection and location for immediate repair.

info@detecsystems.com | ©2003-2010 Detec Systems · All Rights Reserved | Store | Contact Us | Team | Privacy | Sitemap